Accessories
UHF+ID Card
UHF+ID Card: Dual-frequency card: UHF plus RFID ID. Available from LENS in Erbil. Message us on WhatsApp for the price.
Product Name UHF and RFID Dual Frequency Cards Size 54Lx86Dx0.8W(mm) Materal PVC Frequency 915MHz + 125KHz dual frequency Temperature -100℃~+500℃ Colour White ODM&OEM S4A Support Unit Weight 0.01KG Standard Package 200PCS/Bag Carton Weight 1.5KG
ناوی بەرهەم کارتی دوو فرێکوێنسی UHF و RFID قەبارە 54Lx86Dx0.8W(mm) PVC مادەیی فرێکوێنسی 915MHz + 125KHz دوو فرێکوێنسی پلەی گەرمی -100°C~+500°C ڕەنگ سپی پشتگیری ODM&OEM S4A کێشی یەکە 0.01KG پاکێجی ستاندارد 200PCS/جانتا کێشی کارتۆن 1.5KG
اسم المنتج: بطاقات التردد المزدوج UHF وRFID الحجم 54Lx86Dx0.8W (مم) مادة PVC التردد 915 ميجا هرتز + 125 كيلو هرتز تردد مزدوج درجة الحرارة -100 درجة مئوية ~ +500 درجة مئوية اللون أبيض دعم التصميم وتصنيع المعدات الأصلية S4A وزن الوحدة 0.01 كجم الحزمة القياسية 200 قطعة/الحقيبة وزن الكرتونة 1.5 كجم
// BUY IN ERBIL
UHF+ID Card in Erbil — from LENS
LENS has supplied and installed security systems in Erbil since 2012. Message us on WhatsApp for the price, availability and installation of the UHF+ID Card . We are based in Erbil and serve other cities on request.
Ask on WhatsApp// YOU MIGHT ALSO LIKE

Wireless Touch Switch 505E
>Adopt uniformity frequency,high stability of wireless signal receiving and sending >Siludification of PU varnished shell,dapper appearance with anti-off screw >Operation frequency 315M,stability better than 10-5. >Panel pushing with low-power consumption,long service life battery. >Three point of trigger pressing design to ensure the effective action. >With large capacity output,available to be used with autodoor,electric lock and access controller >Door open within 2s when signal received. >Wide voltage input of AC/DC12-36V >Function switch with voice indicator,power indicator turns green to confirm the validity of operation

No Touch With Remote Controller (LP-NT-AR) L-Power
Material: Stainless Steel Output Contact: NO/NC/COM Dimensions # 86L*86W*30H*(mm) No Touch Contactless Door Release Exit Button with Remote Control

Exit Sign Metal Scrap

LD-200 Single Vehicle Loop Detector
■ Install Detector The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as “Loop installation guide”). ■ Operation and Indication While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered. ■ Frequency To eliminate interference of two neighbouring wire loops or loop detectors, the frequency can be altered. ■ Sensitivity The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce an output. There are four sensitivity selections and are set as follows by DIP3 and DIP4 Switch. ■ Automatic Sensitivity Boost Automatic sensitivity boost is selected by DIP5 switch on the front of the enclosure and is set as follows: OFF - Disabled, ON – Enabled. Automatic sensitivity boost causes the sensitivity to be boosted to a maximum on detection on the vehicle, and maintained at this level during the presence of the vehicle over the loop. When the vehicle departs the loop and detection is lost the sensitivity reverts to the pre-selected level. ■ Filter To eliminate interference of bad environment, the filter mode is activated by setting the DIP6 Switch to “ON” site. In filter mode, the reaction time of the detector is delayed, and the sensitivity is reduced. Usually, the filter mode is disabled by setting the DIP6 Switch to “OFF” site. Attention】 If the detector isn’t working normally, you must check the loop and wiring at first, and then alter the frequency or the sensitivity. At last ,try to set it to filter mode. ■ Output Relay The relay2 is pulse output. If DIP7 is “OFF” site, when a vehicle is detected passing over the inductive loop, the relay is energized( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. If DIP7 is “ON” site, when a vehicle is detected departing the loop, the relay is energized ( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. The relay1 is presence output. When a vehicle is detected passing over the inductive loop, the relay is energized( Pin5 and Pin6 are shorted) until the vehicle is detected departing the loop. ■ Presence Time The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop, the presence mode is set with DIP8 Switch and is configured as follows: OFF:Limited Presence ( 5 minutes), ON:Permanent Presence. ■ Reset Switch The detector automatically tunes to the inductive loop connected to it when the power is applied, whether on initial installation or after any break in power supply. Should it be necessary to retune the detector, as may be required after changing any of the switches or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle. ■ Technical Data Product Parameter Parameter Descr1ption Product Name Single Vehicle Loop Detector Supply voltage 230V AC , 115V AC, 12/24V DC/AC ( See the label on the detector) Voltage tolerance AC +10% / -15%; Voltage tolerance DC ±15% Power Consumption 4.5VA Output relays 120V/3A AC Operating temperature -20°C to +65°C Storage temperature -40°C to +85°C Frequency range 20 kHz to 170 kHz Reaction time 10ms Signal holding time Unlimited / limited when loop is permanently covered 5 minutes Sensitivity Adjustable in 4 increments Loop inductance Total loop plus connection wiring 50 to 1000μH.Ideal is 100 to 300μH Loop connection wiring Maximum length 20 meters, twisted at least 20 times per meter Size of Housing 78x40x108 mm (L x W x H)
